内容精选
Content Selection
《英国医学杂志》 研究文章
The BMJ Research
Prediction system for risk of allograft loss in patients receiving kidney transplants: international derivation and validation study [接受肾移植的患者同种移植损耗风险的预测系统:国际上的推导与验证研究]
- 分享:
BMJ 2019; 366 doi: https://doi.org/10.1136/bmj.l4923 (Published 17 September 2019)
Cite this as: BMJ 2019;366:l4923
Authors
Alexandre Loupy, Olivier Aubert, Babak J Orandi, Maarten Naesens, Yassine Bouatou, Marc Raynaud, Gillian Divard, Annette M Jackson, Denis Viglietti, Magali Giral, Nassim Kamar, Olivier Thaunat, Emmanuel Morelon, Michel Delahousse, Dirk Kuypers, Alexandre Hertig, Eric Rondeau, Elodie Bailly, Farsad Eskandary, Georg Böhmig, Gaurav Gupta, Denis Glotz, Christophe Legendre, Robert A Montgomery, Mark D Stegall, Jean-Philippe Empana, Xavier Jouven, Dorry L Segev, Carmen Lefaucheur
Abstract
Objective To develop and validate an integrative system to predict long term kidney allograft failure.
Design International cohort study.
Setting Three cohorts including kidney transplant recipients from 10 academic medical centres from Europe and the United States.
Participants Derivation cohort: 4000 consecutive kidney recipients prospectively recruited in four French centres between 2005 and 2014. Validation cohorts: 2129 kidney recipients from three centres in Europe and 1428 from three centres in North America, recruited between 2002 and 2014. Additional validation in three randomised controlled trials (NCT01079143, EudraCT 2007-003213-13, and NCT01873157).
Main outcome measure Allograft failure (return to dialysis or pre-emptive retransplantation). 32 candidate prognostic factors for kidney allograft survival were assessed.
Results Among the 7557 kidney transplant recipients included, 1067 (14.1%) allografts failed after a median post-transplant follow-up time of 7.12 (interquartile range 3.51-8.77) years. In the derivation cohort, eight functional, histological, and immunological prognostic factors were independently associated with allograft failure and were then combined into a risk prediction score (iBox). This score showed accurate calibration and discrimination (C index 0.81, 95% confidence interval 0.79 to 0.83). The performance of the iBox was also confirmed in the validation cohorts from Europe (C index 0.81, 0.78 to 0.84) and the US (0.80, 0.76 to 0.84). The iBox system showed accuracy when assessed at different times of evaluation post-transplant, was validated in different clinical scenarios including type of immunosuppressive regimen used and response to rejection therapy, and outperformed previous risk prediction scores as well as a risk score based solely on functional parameters including estimated glomerular filtration rate and proteinuria. Finally, the accuracy of the iBox risk score in predicting long term allograft loss was confirmed in the three randomised controlled trials.
Conclusion An integrative, accurate, and readily implementable risk prediction score for kidney allograft failure has been developed, which shows generalisability across centres worldwide and common clinical scenarios. The iBox risk prediction score may help to guide monitoring of patients and further improve the design and development of a valid and early surrogate endpoint for clinical trials.
Trial registration Clinicaltrials.gov NCT03474003.